GOLDENCLAD® PERFORMANCE AND TECHNICAL DATA

Product
Performance Grade
Design Pressure Rating
AAMA/WDMA/CSA 101/I.S.2/A440-08 Standard
Air/Water/Structural
(Canada)
Operating Casement
Max. Size
(35 7/16” x 63”)
PG 50
Design Pressure 50
Class CW-PG50-C
A3, B7, C3
Oversized Casement
(35 7/16” x 76 ¾”)
PG 25
Design Pressure 25
Class CW-PG25-C
A3, B4, C2
Fixed Casement
Max. Size
(70 7/8” x 63” /
63” x 76 ¾”)
PG 50
Design Pressure 50
Class CW-PG50-FW
A3, B7, C3
Picture Window
    Max. Size      
(55.12 ft2 /5.12m2)
 
PG 50 Design Pressure 50 Class AW-PG50-FW Fixed, B7, C3



 
Product
Performance Grade
Design Pressure Rating
AAMA/WDMA/CSA 101/I.S.2/A440-08 Standard
Air/Water/Structural
(Canada)
Doublehung
Max. Size
(39 3/8” x 63”)

 
PG 35 Design Pressure 35 Class R-PG35 A3, B4, C2
Oversized Doublehung
(47 1/4” x 70 7/8”)

 
PG 25 Design Pressure 25 Class R-PG25 A3, B3, C2
Doublehung with HP kit
Max. Size
(47 ¼” x 70 7/8”)

 
PG50 Design Pressure 50 Class LC-PG50 A3, B3, C3
Doublehung Transom Windows
Max. Size
(70 7/8” x 47 ¼”)

 
PG80 Design Pressure 80 Class CW-PG80 FXD, B7, C5
Doublehung Picture Window
Max. Size
(70 7/8” x 63”)

 
PG 75 Design Pressure 75 Class CW-PG75 FXD, B7, C5

 
GOLDENCLAD® OPERATING CASEMENT PERFORMANCE AND TECHNICAL DATA
Low E Surface
Spacer
Grilles
Uimp
SHGC
ER
CANADA
UNITED STATES
ENERGY STAR
ENERGY STAR
Zone(s)
Zone(s)
2
Intercept
-
0.35
0.46
23
A B
 
 
 
 
2
Superspacer
-
0.33
0.46
25
A B C
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3
Intercept
-
0.35
0.49
25
A B C
 
 
 
 
3
Superspacer
-
0.33
0.49
27
A B C
 
 
 
 
GOLDENCLAD® FIXED CASEMENT PERFORMANCE AND TECHNICAL DATA
Low E Surface
Spacer
Grilles
Uimp
SHGC
ER
CANADA
UNITED STATES
ENERGY STAR
ENERGY STAR
Zone(s)
Zone(s)
2
Intercept
-
0.34
0.51
27
A B C
 
 
 
 
2
Superspacer
-
0.33
0.51
29
A B C D
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3
Intercept
-
0.34
0.55
29
A B C D
 
 
 
 
3
Superspacer
-
0.33
0.55
31
A B C D
 
 
 
 
 
 

CANADIAN PRODUCT PERFORMANCE DATA
           
Goldenclad®
  Performance Ratings1 Forced Entry2 Energy Rating3 SHGC4
  CSA-A440 Vent Fixed
Awning          
Insulating Glass A3/B7/C4 F10 -23 -23 0.52
LowE/Argon Gas A3/B7/C4 F10 -9 -10 0.45
Doublehung          
Insulating Glass A3/B3/C1 F2 -22 -17 0.55
LowE/Argon Gas A3/B3/C1 F2 -7 -1 0.51
           

Goldenwood®
  Performance Ratings1 Forced Entry2 Energy Rating3 SHGC4
  CSA-A440 Vent Fixed
Casement          
Insulating Glass A3/B7/C3 F10 -21 -22 0.51
LowE/Argon Gas A3/B7/C3 F10 -8 -9 0.47
Awning          
Insulating Glass A3/B7/C4 F10 -21 -22 0.51
LowE/Argon Gas A3/B7/C4 F10 -8 -9 0.47
Doublehung          
Insulating Glass A3/B3/C1 F2 -22 -16 0.55
LowE/Argon Gas A3/B3/C1 F2 -6 0 0.51
Architectural/Direct Set          
Insulating Glass FXD/B7/C2 N/A - -12 0.67
LowE/Argon Gas FXD/B7/C2 N/A - 6 0.62

Goldenvinyl®
  Performance Ratings1 Energy Rating3 SHGC4 U Value5
  CSA-A440 Intercept Super Spacer® Intercept Super Spacer® Intercept Super Spacer®
Operating Casement A3/B7/C4 26 28 0.49 0.49 1.93 1.82
Fixed Casement FX/B7/C5 31 33 0.56 0.56 1.87 1.82
Operating Awning A3/B7/C4 26 28 0.49 0.49 1.93 1.82
Fixed Awning FX/B7/C5 31 33 0.56 0.56 1.87 1.82
Single Slider A3/FX/B3/C2 29 31 0.57 0.57 1.99 1.93
Double Slider A2/B1/C1 27 29 0.56 0.56 1.99 1.87
Single Hung A3/FX/B7/C2 29 31 0.57 0.57 1.99 1.93
Double Hung A2/B4/C1 28 31 0.56 0.56 1.99 1.87
Picture/Transom FX/B7/C5 35 36 0.62 0.62 1.87 1.82
Sliding Patio Door A3/B3/C3 30 31 0.58 0.58 1.99 1.93
Test values shown above are based on a unit tested with Low E glazing on surface 3 and argon gas.


US PRODUCT PERFORMANCE DATA

Goldenclad®
  ANSI AAMA U Factor5 R Value7 SHGC4
NWWDA 101 I.S.26
Awning        
Insulating Glass AP-R60 0.45 2.22 0.52
LowE/Argon Gas AP-R60 0.34 2.94 0.45



Goldenclad®
  NWWDA 1.S.2-93 U Factor5 R Value7 SC9 SHGC4
  GRADE8 AA BB AA BB
Double Hung  
Insulating Glass 40/40/15 0.49 0.49 2.04 2.04 0.87 0.55
LowE/Argon Gas 40/40/15 0.35 0.34 2.86 2.94 0.82 0.51

Goldenwood®
  ANSI AAMA U Factor5 R Value7 SHGC4
  NWWDA 101 I.S.26
Casement        
Insulating Glass C-R 50 0.46 2.17 0.51
LowE/Argon Gas C-R 50 0.33 3.03 0.47
Awning        
Insulating Glass AP-R60 0.46 2.17 0.51
LowE/Argon Gas AP-R60 0.33 3.03 0.47

Goldenwood®
  NWWDA 1.S.2-93 U Factor5 R Value7 SC9 SHGC4
  GRADE8 AA BB AA BB
Double Hung  
Insulating Glass 40/40/15 0.49 0.49 2.04 2.04 0.87 0.55
LowE/Argon Gas 40/40/15 0.35 0.34 2.86 2.94 0.82 0.51
Picture/Transom/Archtirectural  
Insulating Glass 40/80/25 0.49 0.49 2.04 2.04 0.87 0.67
LowE/Argon Gas 40/80/25 0.32 0.31 3.13 3.23 0.82 0.62

The numbers above represent a small fraction of the total glazing options and configurations offered by Golden Windows. Please check all our glazing option on the Natural Resources Canada website (http://oee.nrcan.gc.ca/residential/energystar-energuide-r2000.cfm?attr=0) or in the United States, please visit, the National Fenestration Rating Council website (www.nfrc.org) for our thermal test results.

Notes:
1. A-Air Tightness
Tested in accordance with ASTM Standard E283, Rate of Air Leakage Through Exterior Windows.
B-Water Tightness
Tested in accordance with ASTM Standard E547, Water Penetration of Exterior Windows, at specified test pressure.
C-Wind Load
Tested in accordance with ASTM Standard E330, Structural Performance of Exterior Windows, at specified test pressure.
Larger numbers indicate better performance.  Level 1 in certain areas is considered to be the minimum requirement for residential construction.

2. F-Forced Entry
An F2 rating indicates the product has been tested in accordance with ASTM Standard F588, Resistance of Window Assemblies to Forced Entry.

3. Energy Rating
Energy Rating (ER) measures overall performance based on the windows ability to admit solar heat, prevent heat loss through frames, spacer, and glass, and resist air leakage heat loss. ER Value is measured in watts per square metre.  The higher the ER Value, the better the window performance.

4. SHGC- Solar Heat Gain Coefficient
The ratio of solar heat gain through a window component to the solar radiation incident on it, for a given angle and for given environmental conditions.  Values are for the total unit.

5. U Value and U Factor
U Value and U Factor indicate the amount of heat loss through a complete window product, due to conduction, convection, and radiation. U Value is measured in watts per square metre.  U Factor is measured in BTU per hour per square foot.  Lower numbers indicate better thermal performance with less heat loss.  Windows have been simulated in accordance with NFRC 100-2004, using the WINDOW 5 and THERM 5 computer programs.

6.
ANSI/AAMA/NWWDA/I.S.2
The NWWDA Rating System is based upon design pressure (DP). Values shown after the window type “C” for casement or “AP” for Awning Projected and followed by “R” for Residential are DP-Ratings (psf) for air filtration, water penetration, and structural testing (ie. 15, 25, 30, etc.). The structural test pressure is 150% of design pressure (DP).

7.
R Value
R Value measures the resistance of a window product to heat flow. Higher values indicate better thermal performance. R Value is numerically equal to the inverse of U Factor.

8.
NWWDA I.S.2-93
The NWWDA Rating System is based upon design pressure (DP). Values shown are DP-Ratings (psf) for air filtration, water penetration, and structural testing (ie. Grades (40/35/40). The structural test pressure is 150% of design pressure (DP).

9.
SC-Shading Coefficient
The ratio of solar heat gain through a window under a specific set of conditions, to the solar heat gain through 1/8” (3mm) sheet of clear glass under the same conditions. Values are for centre glass.






 
  Privacy Statement Disclaimer © Copyright 2008 Golden Windows Limited - All rights reserved